HPMC 10,000 mPa·s — ALC-H100C Tile-Adhesive Grade (C1/C2)

ALC-H100C is a delayed-solubility hydroxypropyl methyl cellulose rated 10,000 mPa·s at 2% in water and 20 °C (Brookfield LV). It sits in the middle of the tile-adhesive window: enough yield stress for C2 anti-sag and skim-coat body, still workable at C1 dosages, with the water retention that keeps a ribbed bed wet long enough to embed a tile.
Grade

ALC-H100C

CAS

9004-65-3

HS code

3912.39

Technical specification

Full parameter table — ALC-H100C

Every value is shown with its test condition. Parameters that are set per batch are confirmed on the batch COA.

Parameter Value Test condition / method
Chemical name Hydroxypropyl methyl cellulose —
CAS number 9004-65-3 —
HS code 3912.39 — Final classification per destination customs.
Appearance White to off-white powder —
Ionicity Non-ionic —
Substitution degree (DS / MS) Methoxyl 19.0–24.0% / Hydroxypropyl 4.0–12.0% Determined per production batch, USP/GB method
Moisture content Max 5.0% % Halogen moisture analyser, 105 °C
pH 5.0–8.0 (1% solution, 25 °C) 1% aqueous solution, 25 °C
Particle size Min 98% through 80 mesh (180 µm) Dry sieving, 80 mesh
Bulk density 300–500 g/L g/L Untapped, as packed
Gel temperature 55–70 °C (2% solution) °C 2% aqueous solution, heating rate 1 °C/min
Ash content Max 5.0% (as sulphate) % Muffle furnace, 800 °C

Typical values for this grade, not a specification guarantee — the contractual figure is the one stated in the COA issued for your batch. Viscosity is measured on a 2% aqueous solution at 20 °C, Brookfield LV, 20 rpm.

How HPMC works in a mortar is the same across grades — see the HPMC category page for the water-retention, anti-sag, open-time and film-forming mechanisms behind every grade. What changes with viscosity is the number and the application band, and those are on this page.

Applications

Where ALC-H100C fits best

ALC-H100C is used in the following systems — Tile adhesive (C1 / C2), Skim coat, Joint filler. Which viscosity band suits which system is set out in the application-and-viscosity table on the HPMC category page .

Not recommended for

  • Premium C2TE adhesives with a slip target of 0.5 mm or better — that class is the specific design point of ALC-H500C.
  • Self-levelling compounds — the yield stress at 10,000 mPa·s is far above what a flowing system can tolerate; use ALC-H4.

A grade that is wrong for the system costs more than the price difference between two grades. Tell us the system and we will tell you if this one is a poor fit.

Batch consistency, export documents and response time do not change with viscosity grade — they are set out under six things procurement can verify on the home page.

Sample, packaging & storage

Before you commit to a container

Free sample

200 g free of charge, shipped from stock. Dispatch arrangements are set out in the sample confirmation.

Packaging

  • 25 kg multi-layer paper bag with PE liner
  • 1,000 kg jumbo bag
  • Custom printing: available on request

Storage & MOQ

Store sealed and dry, below 35 °C, away from direct sunlight. Shelf life: 24 months from production date in the unopened original packaging. MOQ 1 metric ton per grade.

FAQ

Frequently asked questions

What viscosity variation should I expect between batches of ALC-H100C?

Batches typically measure between 9,000 and 12,000 mPa·s against a nominal 10,000 — that is −10% to +20% of nominal. The spread comes from the test method, the test conditions and the instrument, not from a drifting process. The contractual figure is the one stated on the batch COA, measured at 2% aqueous solution and 20 °C.

Why is 10,000 mPa·s described as the middle of the tile-adhesive window?

Because it balances the two failure modes of an adhesive. Too low a band and the ribbed bed slumps on a vertical face; too high and the mix turns short, raises water demand and becomes hard to trowel. At 10,000 mPa·s a C1 and a C2 adhesive can usually share one grade, which is why this band is the volume seller of the series.

Can ALC-H100C be used in wall putty as well?

Yes, it works, and some producers run it precisely so that one grade serves both the adhesive and the putty line. Putty usually wants more body than adhesive, so expect to dose toward the top of the range or to blend. If putty is your main product, ALC-H200 or ALC-H1000 is the more natural fit.

What dosage should I start with for C2?

Start at 0.30 – 0.45% of binder weight, and treat it as a starting point rather than a recommendation: sand grading, cement type and ambient temperature all move the optimum. Slip has to be re-checked whenever the sand source changes, and the final figure belongs in your plant trial record, not in a datasheet.

Get a Quote

Request a quote for ALC-H100C

Tell us the application and the monthly volume and we reply with price, MOQ, packing and lead time in one message. Reply within 12 working hours.

WhatsApp our engineer — ALC-H100C

Send your inquiry

Tell us your application and volume — we reply within 12 working hours.

ALC-H100C

By submitting this form you agree to our processing of your data as described in the Privacy Policy.

Talk on WhatsApp